01 / The pump

Dry vacuum, engineered well

An air-cooled positive displacement pump with self-lubricating vanes and integrated regulation, designed for the rough vacuum range.

No pumping oil

Dry operation eliminates oil changes in the pumping chamber. Filters and vanes still need inspection.

Integrated regulation

The regulating valve adjusts the operating point within the manufacturer’s permitted conditions.

Air-cooled

Ventilation is part of the installation: keep cooling paths clear and follow the operating manual.

Application-led selection

Operating pressure, flow, leakage and electrical supply determine the right configuration.

03 / BECKER specifications

BECKER VT 4.40
Technical specifications

Compare published 50 and 60 Hz data. Voltage, phases and motor configuration must match the nameplate and quoted version.

40nominal m³/h

50 Hz reference · Power 1.25 kW · Noise 67 dB(A)

Original data sheet ↗
BECKER VT 4.40 reference specifications
Parameter50 Hz60 Hz
Nominal flow40 m³/h48 m³/h
Ultimate absolute pressure150 mbar150 mbar
Reference power1.25 kW1.50 kW
Noise level67 dB(A)72 dB(A)
Weight with motor38.5 kg38.5 kg
Vacuum connectionG 3/4G 3/4

Power, weight and dimensions may vary by configuration. Nominal flow and ultimate pressure are not achieved simultaneously: use the curve to determine flow at your operating pressure.

04 / Performance

Performance curves
BECKER VT 4.40

BECKER curves redrawn to explore the operating point. Change frequency, compare both curves and adjust pressure to read approximate values.

50 Hz60 Hz

Reference: 1000 mbar and 20 °C
Published tolerance: ±5%
Data sheet: 4 September 2015 edition

View source PDF ↗

Inlet flow

010203040501503005007001000Flow (m³/h)Inlet pressure (mbar absolute)
150 mbar · Higher vacuum1000 mbar · Lower vacuum
Selected pressure500 mbar
50 Hz reading≈ 32.4 m³/h
60 Hz reading≈ 39.0 m³/h

Approximate values interpolated from the original BECKER plots. Use the slider, click the curve or use the keyboard arrows.

Confirm the supplied version’s curve before sizing. Requirements below 150 mbar absolute need a different solution.

05 / High Performance · Heavy duty

BECKER VX 4.40The X-tra alternative
for demanding duty

When intensive service is your priority, the VX 4.40 offers long-life vanes and an ultimate pressure of 100 mbar absolute. It retains the family’s compact format and dry-running principle.

40 / 48m³/h · 50 / 60 Hz
100mbar absolute
20,000 hPublished X-tra vane life reference

BECKER publishes 20,000 hours or a maximum of 3 years for X-tra vanes, subject to its operating and warranty conditions. Confirm coverage in your quotation. Filters and cooling still require maintenance.

Original BECKER VX 4.40 with blue hood and X-tra branding
VX 4.40 / X-TRA VANE TECHNOLOGY

VT 4.40 vs VX 4.40

50 Hz comparison · Published BECKER data
FeatureVT 4.40VX 4.40 · X-tra
Nominal flow40 m³/h40 m³/h
Ultimate absolute pressure150 mbar100 mbar
Published power1.25 kW1.25 kW
Published noise level67 dB(A)67 dB(A)
VanesSelf-lubricating carbonLong-life X-tra graphite composite
Selection by processIndustrial dry vacuum from 150 mbar absoluteDeeper vacuum and long-life vanes

A lower absolute pressure means a deeper vacuum. Nominal flow is not the available flow at ultimate pressure. The interactive performance charts on this page apply exclusively to the VT 4.40; consult the VX-specific data sheet for that model.

Rollers and sheets in an industrial printing machine
06 / BECKER VT 4.40 applications

Vacuum that connects
your industry

From paper handling to robotic cells. Explore processes where the VT 4.40 can be integrated when its flow curve and vacuum range meet the actual demand.

INDUSTRIAL APPLICATION PHOTOGRAPH / EXPORTVACIO ARCHIVE

One technology, many processes

Find your application

This guide supports selection. Machine compatibility depends on flow, pressure, leakage, the extracted medium and duty cycle; the industry alone does not determine the pump model.

15 applications

Offset printing

Vacuum feeding, separation and transfer of sheets in compatible printing machines.

Selection factor
Check demand per station and paper dust.

Bookbinding & print finishing

Sheet handling in folding, collating, binding and finishing equipment.

Selection factor
Confirm cycles and whether the machine also needs pressure air.

Prepress & CTP

Vacuum hold-down of plates and originals on exposure surfaces.

Selection factor
Check sealing and required holding pressure.

Carton & box forming

Opening cartons, handling trays and positioning items in case packers.

Selection factor
Size for cardboard leakage and simultaneous suction cups.

Automatic labelling

Holding and transferring labels or sheets in compatible applicator heads.

Selection factor
Check the applicator’s instantaneous demand.

Bag & container opening

Container handling in bagging and automatic feeding lines.

Selection factor
Distinguish container opening from deep-vacuum packaging.

Robotics & pick-and-place

Picking, positioning and transferring parts with vacuum grippers.

Selection factor
Validate grip, response time and system safety.

Glass, sheet metal & panels

Handling low-porosity surfaces with suction cups and sealed fixtures.

Selection factor
Calculate load, reserve and protection against vacuum loss.

Woodworking, CNC & hold-down tables

Holding fixtures, small sealed zones or suction cups on machining centres.

Selection factor
Large porous MDF tables may require much higher flow.

Electronics & PCB testing

Holding circuit boards and test fixtures, and handling electronic components.

Selection factor
Check fixture leakage and the number of active points.

Plastics & moulded parts

Removing and transferring parts with suction cups in automated cells.

Selection factor
Check part temperature and grip sealing.

Pharmaceutical & cosmetic packaging

Handling cartons, containers and trays in automated packaging.

Selection factor
Validate hygienic integration for each line.

Cutting tables & flexible materials

Localised holding of sheets, coated fabrics and low-permeability materials.

Selection factor
Porosity and exposed area determine the required flow.

ORIGINAL machinery & test benches

Generating rough vacuum for assembly, testing and automation fixtures.

Selection factor
Define pressure, volume to evacuate and cycle time.

Small networks & receiver systems

Supplying multiple consumers from a correctly sized assembly.

Selection factor
Assess simultaneous demand, reserve, controls and pressure losses.

The standard VT 4.40 is a rough vacuum pump for compatible, dry, clean air. Liquids, vapours, entrained dust or deep-vacuum requirements need assessment and, where appropriate, another technology. The F35 filters particles; it does not turn the unit into a liquid-handling pump.

Application sources and selection criteria

Exportvacio’s technical synthesis of BECKER vacuum applications and VT 4.40 operating limits. Industry references cover families of solutions; they do not certify every machine for this particular model.

Paper & printing ↗Secondary packaging ↗Robotics ↗Electronics ↗CNC & woodworking ↗
07 / Integration accessories

More protection
More comfort

Complete the VT 4.40 or VX 4.40 with external filtration, sound insulation and the controls your process needs.

Original photograph of BECKER F35 filter 74000107000
External filtration

F35 filter

BECKER 74000107000

An additional filtration stage in the suction line, particularly useful where the process generates paper dust or particles. Its cartridge differs from internal filter 909505.

Connection
G 1¼″
Nominal flow
Up to 90 m³/h
Paper cartridge
84040107000
Efficiency
99% at 2 µm

Data from the current manufacturer listing. BECKER lists VT 4.40 Index A/C and VX 4.40 Index C compatibility. Allow for adaptation to the G ¾″ inlet and check pressure losses.

Enquire about F35 ↗
BECKER SH 19 sound enclosure for the VT and VX 4.40 family
BECKER sound insulation

SH 19 enclosure

CATALOGUE REFERENCE 76714053801

Reduces the pump’s acoustic presence in the workplace. It replaces the standard hood with a cooling configuration designed for the pump.

50 Hz · Assembly
56 dB(A)
60 Hz · Assembly
62 dB(A)
Pump family
VT / VX 4.40
Drawing dimensions
806 × 445 × 386 mm

Accessory catalogue values: 2/3 load, both sides piped, DIN EN ISO 3744, KpA = 3 dB(A). These do not guarantee a particular noise level in every installation. Confirm the version and current part reference before ordering.

Enquire about SH 19 ↗

Vacuum gauge & switch

Vacuum measurement and control signals to monitor the operating point.

Fittings & vacuum line

Airtight connections, vacuum-rated hose and a diameter suited to the installation.

Motor protection & control panel

Motor protection and switching sized to the nameplate and available power supply.

Receiver & demand control

Reserve capacity and control where simultaneous demand or the process requires them. Subject to engineering assessment.

Your configuration, in one enquiry

Select your pump and accessories to add them to the quotation assistant.

You review and decide when to send.

08 / Tank-mounted vacuum systems

One, two or three pumpsA system built around you

Integrate 1, 2 or 3 VT 4.40 or VX 4.40 pumps into a central receiver system. D1, D2 and D3 configurations support planning for capacity, alternating duty and standby according to your installation’s demand.

The receiver provides buffer volume and helps manage cycles. Its size, controls and pipework are selected around required flow, leakage and operating pressure.

BECKER VT 4.40 system with receiver, SH 19 enclosure and control panel
BECKER-documented assembly: VT 4.40 with SH 19, receiver and control panel
Installed pumps
D2 · 2 × BECKER VT 4.40 · 50 Hz
40 m³/hNominal flow of duty pumps
Installed nominal capacity
80 m³/h
Pump allocation
1 duty / 1 standby
Ultimate pressure per pump
150 mbar abs.
Indicative calculation: number of duty pumps × nominal flow per pump. It does not represent usable flow at a given pressure or deduct filter and pipe losses. Parallel pumps increase capacity; they do not lower ultimate pressure. Standby capacity is excluded from the displayed duty flow. This does not replace system sizing.

Industry

Centralise handling, printing, packaging or workholding stations. Duplex or triplex configurations support planning for sequencing and maintenance with standby capacity.

Clinics & laboratories

Plan a solution for auxiliary services compatible with dry vacuum. Clinical suction requires a separate assessment of liquid, contamination and backflow protection.

Hospitals

Treat a medical vacuum plant as a complete project: simultaneous demand, redundancy, filtration, separators, alarms and supply continuity.

Healthcare suitability is validated at system levelThese configurations are engineering proposals, not a medical vacuum certification. Patient suction requires validation of effective pressure and flow, redundancy, alarms, filtration and applicable local standards. BECKER offers dedicated medical systems; a VT or VX pump with a tank does not by itself establish NFPA 99 or other healthcare compliance.

What to define before requesting a system quotation

Industrial, auxiliary or medical use; simultaneous points; flow at the required pressure; demand cycle; reserve autonomy; receiver volume; duty and standby pumps; voltage, phases and frequency; room ventilation; condensate handling; filtration; isolation and non-return valves; controls, alarms and indicators. Verify capacity at the operating point.

09 / Acoustic engineering · SH 19

Less noiseMore workplace comfort

Explore published noise levels for the VT 4.40 with its standard hood and the VT / VX 4.40 with an SH 19 enclosure. Switch frequency and view the declared uncertainty.

Published noise: 67 dB(A) standard and 56 dB(A) with SH 19, different test conditions01020304050607080Standard hood67 dB(A)With SH 19 enclosure56 dB(A)Sound pressure level · dB(A)
VT 4.40 data sheetSH 19 catalogue
11 dB difference between published values

Published values at 50 Hz · 67 / 56 dB(A)

Documentary comparison, not guaranteed attenuation. The pump data sheet specifies 1 m distance, medium load and both sides piped; the enclosure catalogue specifies 2/3 load. Conditions are not identical. Actual noise depends on installation and should be measured at the workplace. Decibels use a logarithmic scale.

BECKER SH 19 sound enclosure for VT 4.40 and VX 4.40

BECKER SH 19

Technical data for the 4.40 variant

Published enclosure and assembly data
SH 19 reference for VT / VX 4.4076714053801
Published level · 50 / 60 Hz56 / 62 dB(A)
Total mass · pump + SH 1942 kg
Overall envelope shown in drawing806 × 445 × 386 mm
Vacuum connection shown3/4″
4.40-specific drawing dimensionse = 290 · f = 362 · g = 40 mm
Dimensions not applicable to this variante1 / g1 / g2: —
InstallationReplaces the standard hood
ApplicationDry-running VT 4.40 / VX 4.40 rotary vane pumps
Enclosure acoustic test2/3 load · both sides piped
Published standard and uncertaintyDIN EN ISO 3744 · KpA = 3 dB(A)

The 42 kg mass includes the pump. The official drawing details fixings, cable entry and terminal box location. Confirm the revision and installation for the supplied unit.

10 / Electrical and vacuum connections

Integration
done properly

Reference guide for installing a standard VT 4.40 or VX 4.40. The supplied unit’s nameplate and terminal-box diagram determine the final connection.

Suction circuit

ProcessVacuum consumer
Optional F35External filter
Line & instrumentationMeasurement & regulation
VT / VX 4.40G ¾″ inlet

Airflow: process → pump. The F35 has a G 1¼″ connection; adapt the fitting without restricting the line. Exhaust and cooling airflow must remain unobstructed.

Power supply & protection

SupplyV, Hz and phases
DisconnectIsolation
Protection & controlMatched to the motor
MotorTerminals per nameplate

PE · Protective earth to motor
Functional integration diagram, without universal terminal bridges. Wiring must be carried out by a qualified electrician with the equipment isolated.

VT 4.40 connections

Standard-model reference · See manual sections 6.2 and 6.3 and motor documentation
Connection pointData or criterionWhat to confirm for your project
SuctionVT 4.40 / VX 4.40: G ¾″The VT 4.40/0-90 variant uses G 1″. Identify the complete model.
External F35 filterG 1¼″ · 74000107000Fittings, orientation, accessibility and pressure loss.
Vacuum pipeworkDiameter at least equal to the nominal connection sizeFor lines longer than 2 m, the manual specifies the next size up; review the route.
Non-return valveRecommended by BECKER for lines longer than 5 mCompatibility with system reserve and switching.
Voltage and phasesAccording to motor nameplate and destination supplyProvide V, Hz, 1~ / 3~ and a nameplate photograph. There is no universal supply voltage.
Terminals and protectionTerminal-box diagram and overload protectionCurrent, service factor, earthing and direction of rotation.
Starting frequencyPublished maximum: 10 starts/stops per hourFor rapid cycles, assess vacuum control with continuous pump operation.
Control panel and enclosureProtection and cooling according to the supplied configurationConfirm switching, signals and fans if fitted to the version supplied.
11 / Vanes and spare parts

BECKER VT 4.40 spare parts
The exact reference

WN 124-161

BECKER identifies this designation with set 90135200007 of seven carbon vanes. Its catalogue covers VT 4.40 Index A and C; always check the version and serial number before ordering.

90135200007BECKER order number
7 vanesCarbon set · WN 124-161
BECKER WN 124-161 vane set, reference 90135200007
Vane reference · Compatibility by version and serial number
VT 4.40 vanes · Three references to identify the replacement
ReferenceIdentificationScope
WN 124-161BECKER vane designationVT 4.40 family · check index and serial number
90135200007BECKER order numberSet of seven vanes
H95434/7HARDVANES alternative referenceSet of seven · 95 × 43 × 4 mm · aftermarket part, not an original BECKER part

Looking for H63434? HARDVANES lists H63434/7 for the 3.25 / 4.25 family, measuring 63 × 43 × 4 mm. It is not the published reference for VT 4.40. The documented third-party reference for this pump is H95434/7. Confirm the model, nameplate and index before purchase; these references do not automatically apply to VX X-tra vanes.

Vanes

Check wear and replacement limits in your unit’s manual.

Filtration

Inspect the inlet filter and confirm its reference before replacement.

Cooling

Keep ventilation and cooling surfaces clear as instructed by BECKER.

12 / Filtration and sealing

Performance starts
with every detail

Two essential replacement components for your VT 4.40: the inlet filter and the side-cover gasket.

72Original BECKER 90950500000 filter for VT 4.40
Inlet filtration

909505 filter

90950500000

Paper cartridge located at position 72 in the Index A and C exploded views. The complete order number avoids confusion with other cartridges in the family.

99 %Efficiency at 2 µm
64 × 38 × 70Published dimensions · mm

Inspect, clean or replace the element according to your unit’s manual and process dust conditions. BECKER specifies clean, dry compressed air for cleaning the paper cartridge.

30Original BECKER 00890016500 side-cover gasket for VT 4.40
Side-cover gasket

BECKER gasket

00890016500

Gasket identified at position 30 in the VT 4.40 Index A and C catalogues, beside the pumping assembly’s side cover.

Pos. 30Gasket / seal
Index A / CDocumented reference

When planning side-cover maintenance, identify the gasket using the exploded view for your version. Request it by its full reference and provide the pump nameplate.

Identification checked against BECKER documentation
13 / Engineering revealed

The VT 4.40
Part by part

An interactive vector exploded view adapted from BECKER drawings. Choose your nameplate index and select a number to see the component and its reference.

Nameplate index
100 %
BECKER VT 4.40 Index A exploded viewVector drawing adapted from the BECKER exploded view. Select a number to see its reference. Position 74 applies to the /0-65 variant.726791786189112887677124901112321152418191750494648979896959483851272529302892161041011021037467

VT 4.40 / Index A / 11.2013

Click drawing numbers or use the catalogue. Zoom and pan the drawing; use Tab to enter the drawing and arrow keys to move between positions. Position 74 applies to the /0-65 variant.

Parts catalogue and reference numbers

43 positions · Index A
BECKER VT 4.40 Index A parts
Pos.ComponentBECKER referenceDrawing
15Rotor02000016500
16Clamping disc01680016500
17STAR tolerance ring91100800000
18Toothed washer94920300000
19Hexagon socket screw94532000000
21Pump housing00010216500
23Hexagon socket screw94532200000
24Set of 7 carbon vanes90135200007
25Locating pin95200900000
28Side cover00071016500
29Hexagon socket screw94537400000
30Side-cover gasket00890016500
46Fan with hub90230026200
48Key94771300000
49Washer94945400000
50Shaft-end screw90180400000
61Filter cover00480327600
67Compression spring00900016300
72Inlet filter cartridge90950500000
74Filter cartridge · /0-65 variant90952900000
76Hexagon socket screw94537300000
77Sealing ring94802100000
78O-ring91316100000
83Protective cover00680127600
85Rubber element95192000000
88Front protective cover00680227600
89Spacer06800027500
90Hexagon socket screw94532000000
91Rubber element95192200000
92Edge protector96410900000
94Support foot01510027600
95Rubber element95192100000
96Spacer sleeve06800027600
97Hexagon socket screw94532800000
98Washer94945100000
101Valve plate83390399597
102Rubber cable grommet95190600000
103Spacer tube06800216500
104Lifting eye54880016300
111O-ring91316100000
112Rubber washer74130027600
124Vacuum regulating valve73600199613
127Blow-off valve72750206000

Your nameplate identifies
the right replacement

The standard catalogue contains 42 positions in Index A and 41 in Index C. The viewer also includes position 74 for the /0-65 variant. References may vary by version and change over time: confirm the complete model, index and serial number before ordering. Identify the motor and its components using the motor nameplate; this drawing does not replace service instructions.

Single-phase and /0-65 variant references

Variations documented in the Index A and C catalogues. Depending on the version, these references replace or supplement the standard assembly parts.

VariantPositionComponentReference
Single-phase 1~13Cable74200230000
Single-phase 1~83Protective cover00680527600
Single-phase 1~94Support foot01510127600
/0-6521Pump housing00010016500
/0-6528Side cover00070016500
/0-6574Filter cartridge90952900000
/0-6583Protective cover00680627600
14 / Documentation

Everything you need
In one place

Data sheets, instructions and exploded views to select, install and maintain your pump. Check that each document matches your version.

Technical data sheet

Flow, curves, dimensions and reference configuration

Open document ↗

Exploded view and parts catalogue

Components and references for spare parts identification

Open document ↗

View dimensional drawing and motor table

Reference document, 4 September 2015 edition. Confirm the drawing and motor for the supplied version.

BECKER VT 4.40 dimensional drawing and reference motors
Production line in an industrial plant
1,000+units supplied by Exportvacio

Accumulated supply figure reported by Exportvacio · October 2026

15 / Experience serving your industry

Your trusted partner
in Latin America

Industrial supply starts with the right selection and continues with spare parts, documentation and support. Exportvacio brings that experience to industries that depend on continuity.

International supplyIdentified spare partsTechnical documentation
16 / Clear answers

Before you decide

Questions that help you choose the right pump and identify the correct replacement part.

Can I build a central system with two or three VT 4.40 pumps?

Yes, a D2 or D3 receiver system with controls can be considered. At 50 Hz, two and three pumps total 80 and 120 m³/h nominally when all run. With one standby pump, nominal duty capacity falls to 40 and 80 m³/h. Verify usable flow at operating pressure.

Is a VT 4.40 with a receiver ready for hospital vacuum use?

A pump and tank do not certify a medical vacuum plant. Hospitals and clinics require validation of the complete system: flow, pressure, redundancy, alarms, filtration, liquid separation and applicable standards. Exportvacio reviews the specification before proposing equipment.

What noise level does BECKER publish for the SH 19 enclosure?

The catalogue publishes 56 dB(A) at 50 Hz and 62 dB(A) at 60 Hz for VT / VX 4.40 with SH 19. The standard VT 4.40 sheet states 67 and 72 dB(A) under different test conditions; the difference is not guaranteed attenuation for every installation.

Is H63434 a VT 4.40 vane reference?

HARDVANES identifies H63434/7 with the 3.25 / 4.25 family. For VT 4.40 it lists H95434/7, an alternative set of seven 95 × 43 × 4 mm vanes. The BECKER references on this page are WN 124-161 and 90135200007.

What is the BECKER VT 4.40 flow rate?

Nominally 40 m³/h at 50 Hz and 48 m³/h at 60 Hz. Check the curve for flow at operating pressure and account for installation losses.

What does 150 mbar absolute mean?

It is ultimate pressure referenced to absolute vacuum. With a reference atmosphere of 1000 mbar, it represents an 850 mbar pressure difference. Always specify whether measurements are absolute or relative.

Does it need oil?

It uses no pumping oil in the compression chamber. The vanes are self-lubricating, but filters, vanes and cooling require maintenance.

Can it run continuously?

It is designed for continuous operation within the manufacturer’s conditions, with suitable ventilation, filtration and maintenance.

What should I confirm when replacing another VT 4.40?

Complete model, version, serial number, electrical supply, connections and installation space. A clear nameplate photograph helps identify the correct replacement.

Do WN 124-161 and 90135200007 identify the same set?

BECKER associates WN 124-161 with set 90135200007 containing seven carbon vanes. Confirm compatibility with your version and serial number before ordering.

Is it suitable for every packaging process?

The application must be assessed. Processes requiring below 150 mbar absolute or media not permitted for this version require another solution.

Which filter does the BECKER VT 4.40 use?

BECKER Index A and C catalogues identify inlet filter 90950500000, also searched as 909505, at position 72. Confirm your unit’s version before ordering.

Where is gasket 00890016500 located?

It is the side-cover gasket, position 30 in the VT 4.40 Index A and C exploded views. Find it in the interactive viewer and request it by its full reference.

Why are there Index A and Index C exploded views?

BECKER distinguishes versions through the nameplate index. Some references change, including the filter cover at position 61. Select the correct index to consult the matching catalogue.

What is the difference between BECKER VT 4.40 and VX 4.40?

Both publish 40 m³/h at 50 Hz and 48 m³/h at 60 Hz. The standard VT reaches 150 mbar absolute and the VX 100 mbar. The VX uses long-life X-tra vanes. Compare using your installation’s frequency in the VT vs VX section.

What does High Performance or heavy duty mean for the VX 4.40?

On this page it describes its focus on intensive service and X-tra vanes. It is not an additional certification or a claim of higher nominal flow than VT 4.40. Selection still depends on pressure, flow and process conditions.

Does the F35 replace cartridge 909505?

No. The F35 is an external filter with its own cartridge 84040107000. The 90950500000 is the internal inlet cartridge for the VT 4.40 versions identified in the exploded view. They are separate components.

Can a sound enclosure be added?

The BECKER catalogue lists SH 19 for VT and VX 4.40. Its acoustic data refers to specific test conditions. Confirm compatibility and the current reference against your pump nameplate.

What is the best 40 m³/h dry vacuum pump for my industry?

At Exportvacio, the VT 4.40 is our benchmark choice for compatible processes because of its dry operation, regulation and accessible maintenance. The best selection for your machine depends on the flow curve, required vacuum, leakage and cycle. The VX 4.40 adds deeper vacuum and X-tra vanes.

What electrical connection does the VT 4.40 require?

It depends on the supplied motor. Check voltage, phases and terminal bridges against the nameplate and terminal-box diagram. Provide these details and the installation country to specify motor protection and controls.

How do I request pricing and availability?

Complete the assistant with destination, quantity, frequency, voltage and application. Configuration, availability, price and lead time are confirmed in the commercial quotation.

17 / Exportvacio

Let’s discuss
your process

Prepare a technical enquiry and review it before continuing by WhatsApp or email. Our team will confirm the equipment selection.

+376 380 938comercial@exportvacio.com

This assistant prepares a summary and does not send information automatically. Fields are not stored on this page.

BECKER VT 4.40 / ExportvacioContent reviewed on 15 October 2026Oil-free vacuum pump range ↗
Enlarged view of the BECKER VT 4.40 vacuum pump

Ilustración

BECKER VT 4.40 · Visitor ratingsVotes submitted on this product page. Purchases are not verified.
4.6/5 · 39 votes